To meet the customers' over-expected satisfaction , we have our strong team to provide our best overall service which includes marketing, sales, designing, production, quality controlling, packing, warehousing and logistics for Data Center Rack PDU, Power Distribution Unit, Smart PDU, Because we stay in this line about 10 years. We got best suppliers support on quality and price. And we had weed out suppliers with poor quality. Now many OEM factories cooperated with us too.
ODM High Quality USA PDU Manufacturer – 3-phase Intelligent PDU rack mount power distribution unit – Newsunn Detail:

Features

● Modular structure for easy customization. Compatible with most of standard outlets with CE, GS, UL, NF, EESS and other major popular certification.

● Remote Monitoring and controlling. Provides immediate updates about power events via email, SMS text, or SNMP traps Upgradeable Firmware. Downloadable firmware updates to improve programs that run the PDU.

● Digital Display. Provides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information.

● Network-Grade Plugs and Outlets. Highly durable construction ensures the efficient distribution of power to servers, equipment, and connected devices in demanding IT or industrial environments.

● Durable Metal Casing. Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.

● Three-Year Limited Warranty. Cover defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date.

Functions

Newsunn intelligent PDUs have A, B, C, D models. A & B types have the function of remote monitoring and remote controlling: A type can implement total circuit and branch circuit monitoring and controlling; B type only can implement the total circuit monitoring and controlling. C & D types have remote monitoring function: C type can monitor both of the total circuit and branch circuit; D type can only monitor the total circuit. The below table is much more easy to see the difference.

Main function

Technical instruction

Function Models
A B C

D

Monitor Total load current

Load current of each outlet  
On/Off state of each outlet    
Total power(kw)

Total energy consumption(kwh)

Work voltage

Frequency

Temperature/Humidity

Smog sensor

Door sensor

Water logging sensor

Control On/off of the power    
On/off of each outlet      
Set the interval time of outlets’ sequential on/off      
Set the on/off time of each outlet      
Set limiting value to alarm The limiting range of total load current    ●    ●
The limiting range of load current of each outlet    
The limiting range of the work voltage
The limiting range of temperature and humidity
System automatic alarm The total load current exceeds the limiting value
The load current of each outlet exceeds the limiting value
Temperature/Humidity exceeds the limiting value
Smog
Water-logging
Door opening

Technical Parameters

Item

Parameter

Input

Input Type AC 1-phase, AC 3-phase,-48VDC, 240VDC,336VDC
Input Mode Power cord, industrial socket, sockets, etc.
Input Voltage Range 100-277VAC/312VAC-418VAC/100VDC-240VDC/-43VDC- -56VDC
AC frequency 50/60Hz
Total load current 63A at maximum

Output

Output voltage rating 220 VAC,250VAC,380VAC,-48VDC,240VDC,336VDC
Output frequency 50 /60Hz
Output standard IEC C13, C19, German standard, UK standard, American standard, industrial sockets IEC 60309 and so on
Output quantity 48 outlets at maximum

Drawing

Communication Function

● Users can check the function configuration parameters and power control of the remote device via WEB,SNMP.

● Users can quickly and easily upgrade the firmware via network download for future product enhancement instead of

replacing the products already installed in the field when new features are released.

Interface and Protocol Support

● HTTP
●  SNMP V1 V2
● MODBUS TCP/IP
● MODBUS RTU(RS-485)
● FTP
● IPV4 Support
● Telnet

Accessory

Socket Type


Product detail pictures:

ODM High Quality USA PDU Manufacturer –  3-phase Intelligent PDU rack mount power distribution unit – Newsunn detail pictures

ODM High Quality USA PDU Manufacturer –  3-phase Intelligent PDU rack mount power distribution unit – Newsunn detail pictures

ODM High Quality USA PDU Manufacturer –  3-phase Intelligent PDU rack mount power distribution unit – Newsunn detail pictures

ODM High Quality USA PDU Manufacturer –  3-phase Intelligent PDU rack mount power distribution unit – Newsunn detail pictures

ODM High Quality USA PDU Manufacturer –  3-phase Intelligent PDU rack mount power distribution unit – Newsunn detail pictures


Related Product Guide:

Persisting in "High top quality, Prompt Delivery, Aggressive Price", now we have established long-term cooperation with customers from the two overseas and domestically and get new and aged clients' large comments for ODM High Quality USA PDU Manufacturer – 3-phase Intelligent PDU rack mount power distribution unit – Newsunn , The product will supply to all over the world, such as: Thailand, Singapore, Brazil, Immediate and specialist after-sale service supplied by our consultant group has happy our buyers. Detailed Info and parameters from the merchandise will probably be sent to you for any thorough acknowledge. Free samples may be delivered and company check out to our corporation. n Morocco for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Cora from Kyrgyzstan - 2018.06.21 17:11
    The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Irene from Ghana - 2018.11.28 16:25

    Build your own PDU

    Write your message here and send it to us

    Build your own PDU